BY9800-B吊秤仪表英文版标定方法

1 press the "目/C" button to display the "parameter setting" interface.
2 Press 2 system settings, display the password "000000"".
3 enter six password "111111", press "confirm" button, display "system settings".
4 Press "1" system calibration, display system calibration interface, note that the 1-3 number parameters, please do not press.
5 when empty scale, press the "4" key, Zero to confirm, confirm success and showing “finish”.
6 hang up the weight, wait for 5 seconds, after the stability, press "5" key, and then enter "weight value" (press “100” if it is 100kg), press "confirm".
7 press the "目/C" button 3 times, return to the weighing interface, it will show the weight component.